Troubleshooting & maintenance

Why is my vape spitting?

Why is my vape spitting?

Spitting, or spitback, means that droplets of liquid splash or travel up through the mouthpiece. It is not the same as a crackling sound from heating or the small droplets in the aerosol. Stop activation if liquid droplets or hot liquid come up through the mouthpiece.

Excess liquid at the coil, liquid in the airflow path, filling, and damaged parts can cause spitting.

Why does a vape spit?

Liquid feeding, heating, and airflow work together. Spitting can occur when excess liquid is present near the coil or when liquid has already collected in the air channel.

Too much e-liquid around the coil

Overfeeding provides more liquid at the heating surface than is vaporized. Local vapor formation can then drive droplets upward.

Overfilling, unsuitable viscosity, or liquid in the airflow path can contribute. The filling area and air channel are different parts of the construction. The processes are also explained in the article about why e-juice sometimes ends up in the airflow channel.

Power and liquid feeding

Power that is too low in relation to the coil’s intended range and the feeding rate can leave excess liquid. Do not increase the power to try to use up the droplets.

Innokin, for example, specifies 10–14 W for the Z KAL Coil 1.6 ohm in a compatible adjustable device. On a pod without a wattage control, the power cannot be adjusted manually. The power concepts are explained in the article about watts, volts, and puff counters in a vape.

Incorrect e-liquid can contribute to spitting

Viscosity affects feeding through the wick and openings. Liquid that is too thin can cause overfeeding in a particular construction. Liquid that is too thick can instead cause insufficient feeding and affect taste and function. Pod size alone does not determine which blend is suitable.

For the Innokin Go-Z, the manufacturer specifies both 50 VG/50 PG and 70 VG/30 PG. For the GoMax, 70 percent VG or more is stated as suitable. The differences are explained in the article about which e-liquid is suitable for different vapes. E-liquid can have different compositions even when the bottle format is the same.

Overfilled pod or tank

Overfilling or filling through the wrong opening can bring liquid into the air channel and cause bubbling, gurgling, or droplets in the mouthpiece. The container’s filling opening must be distinguished from the airflow path. Do not overfill the intended refillable container.

The Aspire Flexus Pro is filled through the opening behind the silicone seal on the side of the pod. The seal is closed after filling. A sealed, prefilled pod should not be opened or filled with your own liquid.

Inhalation and liquid flow

Strong or rapid draws can create negative pressure that increases feeding in some constructions.

Liquid can also collect in the air channel from the aerosol flow. Longer, harder, or repeated draws should not be used to empty the channel or test whether the problem disappears.

Condensation can be mistaken for spitting

Liquid already present in the mouthpiece or air channel can travel with the airflow. Gaseous components can condense when cooled, and aerosol droplets can stick to surfaces. This is a different process from liquid splashing directly from the heating surface.

Accessible surfaces can be wiped dry on equipment that is switched off, cool, and disconnected. More about the origin and handling can be found in the article about why some pods get condensation underneath the pod.

Can an old coil cause spitting?

Deposits or damaged liquid-absorbing material can change feeding and heating.

Residue from flavor ingredients and sweeteners can affect function over time. Weak flavor or uneven aerosol can also have other causes, such as feeding, power, or connection. If there is a dry or burnt taste, activation should be stopped. Burnt cotton is not restored by refilling or cleaning. Construction and wear are discussed in the article about how a pod wears out over time.

Is it dangerous when a vape spits?

Yes. Hot liquid can reach the mouth and cause injury. Stop when droplets come up through the mouthpiece. E-liquid may contain nicotine and must not be swallowed.

Seek advice in cases of suspected poisoning without waiting for symptoms. Call the Poisons Information Centre at 010-456 6700 in less urgent cases. When it is urgent, call 112 and ask for the Poisons Information Centre.

The difference between spitting and gurgling sounds

Gurgling is a sound that can occur when air passes through liquid in the air channel. Spitting refers to droplets moving toward the mouthpiece. Crackling from heating is another observation and does not prove that liquid is coming out.

The processes can overlap when there is excess liquid. Both sounds and droplets can occur in a vape. More about the causes of the sound can be found in the article about why a vape makes gurgling sounds.

Example: why does a new pod sometimes spit?

A new pod can develop excess liquid through filling, feeding, or deposits from the aerosol. Stop using it if it spits; the problem should not be waited out with more activations.

A new coil needs to be thoroughly saturated before the first activation. For the Innokin Go-Z, wetting the accessible wick, filling, and waiting at least five minutes are specified.

Incorrect filling, unsuitable liquid feeding, or damaged parts may also be present from the start. Other changes in new pods are discussed in the article about why a new pod may feel different during the first few days.

How can you reduce the risk of vapes spitting?

Correct filling, assembly, and liquid can help prevent excess liquid. If spitting occurs, stop using the device rather than continuing with test puffs.

  • E-liquid: the blend should suit the construction’s feeding system and materials.
  • Filling: use the intended filling opening, not the air channel. Do not overfill, and close the filling seal afterward.
  • Assembly: the pod and coil should fit correctly. A damaged or incompatible part should not be forced into place.
  • Power: use the coil’s intended range, for example 10–14 W for the Innokin Z KAL 1.6 ohm. Do not increase the power to try to remove droplets.
  • Wiping: disconnect the charging cable, switch off the device, and let the parts cool. Wipe only intended accessible surfaces on the mouthpiece and contact surfaces with a dry, soft cloth. Do not rinse or open the electronics, and do not bend the contact pins.
  • Replacement: replace a burnt coil or damaged part with the intended spare part.

The Aspire Flexus Pro has a pod with a replaceable AF coil and a pod with a fixed coil, respectively. In the first, the coil module is replaced; in the second, the pod section is replaced. A cracked pod cannot be repaired by replacing only the coil. Sealed pods should not be opened for self-cleaning or filling.

If problems recur, stop using the device rather than continuing with test puffs, blowing through it, or heating pulses. If there is abnormal heat, damage, swelling, unintended activation, or suspected liquid in the electronics, stop both use and charging.

Quick Facts