“Atomizer short” means that the electronics have detected a short circuit in the circuit to the atomizer, where the coil is located. The protection stops the power output. Stop using the device and turn it off before handling removable parts.
How does Atomizer Short differ from other messages?
Eleaf iStick Pico 25 distinguishes between “Atomizer Short” for a short circuit, “Atomizer Low” for resistance that is too low, and “No Atomizer” when no atomizer is connected. On the Pico 25, “Atomizer Low” is displayed below 0.1 ohms in VW/Bypass and below 0.05 ohms in TC.
What can cause the short-circuit message?
- The coil: incorrect installation or damage to the heating wire or insulation can affect the circuit.
- The connection: dirt, condensation or liquid can interfere with the contact.
- The tank or pod: cracks, damaged contacts or threads can affect the connection.
- The mod: a fall or liquid ingress can damage the battery unit or electronics.
The error message points to the circuit problem but does not identify the faulty part.
What can be checked with the device turned off?
Disconnect the charging cable and let the device cool down. In the event of damage, abnormal heat or suspected liquid in the electronics, do not use or charge the device, or carry out further checks involving activation.
- Coil installation: only remove a coil intended to be replaced. Screwed-in coils are unscrewed; push-fit coils are pulled out. Aspire Flexus Pro is available with a replaceable AF coil and with a fixed coil. With a fixed coil, the entire pod is replaced.
- Reassembly: install a compatible replaceable coil straight and fully into place without forcing the threads. Do not open the coil head or move the cotton. How to change a coil describes the designs.
- Contacts: wipe accessible surfaces with dry paper or a dry cotton swab. Do not insert material into the electronics or charging port, and do not bend the pins. Do not use metal tools.
- Tank and pod: look for visible cracks or damaged seals, threads and contacts. Replace a damaged intended removable part with the correct spare part. Do not open a sealed pod or battery compartment.
- Spare parts: the model designation, fit and visible condition can be compared with an undamaged compatible spare part. Do not activate a faulty or suspected damaged device to determine the cause.
What should I do if the problem persists?
Refrain from further activations and contact support@cigge.se. State the device model, tank or pod, coil designation and resistance, as well as the exact error text. Describe when the problem started, any falls, heat or liquid, and the checks carried out while the device was turned off.
Persistent faults may require technical troubleshooting. Do not open the mod, repair the circuit board or attempt to bypass the protection.
How should installation and filling be handled?
Install the correct coil series and other compatible parts without using force. Keep accessible connections clean and dry. Fill through the filling opening, never the central airflow channel, and close the filling port afterwards without exceeding the maximum level.
The coil fit, the device’s resistance range and the operating mode need to match. The same ohm rating or a thread that fits is not enough. Replace damaged or worn parts when necessary; there is no common replacement interval for all designs.
Quick Facts